bandera
Hogar Cable autorregulador Resistance Self-regulating Cable

Mineral-Insulated Single-Core Resistance Cable JSM

Mineral-Insulated Single-Core Resistance Cable JSM

It is designed for trace heating of extended pipelines, including in explosion-hazard areas.

 

 
  • Tensión nominal :

    up to 660V
  • Temperatura máxima sin energía :

    200°C

Mineral-Insulated Single-Core Resistance Cable Specification: 

Heat release power: up to 250W/M

Maximum operating temperature:

Copper (C, up to 40 W/m) up to +200 °C

Copper-nickel alloy (CN, up to 110 W/m) up to +400 °C

Stainless steel (SS, up to 250 W/m) up to +600 °C

Min. installation temperature: -60 °С

Nominal size(diameter): 3.1 to 6.5mm

Protection rating: IPX6

Temperature class: T1, T2, Т3

Rated voltage: up to 660V

Explosion-protection type: 1ExellCТ1...Т6GbX

 

Mineral-Insulated Single-Core Resistance Cable Design:

1. Heating core

2. Mineral insulation

3. Copper/copper-nickel alloy/stainless steel sheath

 

Mineral-Insulated Single-Core Resistance Cable Features:

• Full noncombustibility of the heating cable

• High mechanical strength and resistance to crushing

• High corrosion resistance as well as resistance to oils, sea water, petroleum, and other aggressive media

• High dependability in operation

• High continuous permissible operating temperatures (up to 600 °C depending on the sheath material)

• A possibility of manufacturing“installation wires”of any length

• Simple and easy installation

dejar un mensaje
Si está interesado en nuestros productos y desea conocer más detalles, deje un mensaje aquí, le responderemos lo antes posible.

Productos relacionados

Two-Core Resistance Cable JTS-RD
Two-Core Resistance Cable JTS-RD

Anti-icing heating systems for roof components.  Heating systems for outdoor areas, steps, and ramps.  

Detalles
Single-Core Resistance Cable JTS-RS
Single-Core Resistance Cable JTS-RS

Anti-icing heating systems for roof components.  Heating systems for outdoor areas, steps, and ramps.  

Detalles
Mineral-Insulated Single-Core Resistance Cable JSM
Mineral-Insulated Single-Core Resistance Cable JSM

It is designed for trace heating of extended pipelines, including in explosion-hazard areas.    

Detalles
Three-Core Resistance Cable JLT
Three-Core Resistance Cable JLT

It is designed for trace heating of extended pipelines, including in explosion-hazard areas.    

Detalles
Two-Core Resistance Cable JHT
Two-Core Resistance Cable JHT

They are intended for heating of foors and other outdoor sites in explosion-hazard areas.  

Detalles
Two-Core Resistance Cable JTS
Two-Core Resistance Cable JTS

They are intended for heating of foors and other outdoor sites in explosion-hazard areas.  

Detalles
Single-Core Resistance Cable  JRT
Single-Core Resistance Cable JRT

It is designed for trace heating of pipelines, including in explosion-hazard areas.  

Detalles

dejar un mensaje

dejar un mensaje
Si está interesado en nuestros productos y desea conocer más detalles, deje un mensaje aquí, le responderemos lo antes posible.
entregar

Nuestro horario

Lun 21/11 - Miércoles 23/11: 9 a.m. - 8 p.m.
Jueves 24/11: cerrado - ¡Feliz Día de Acción de Gracias!
Viernes 25/11: 8 a.m. - 10 p.m.
Sábado 26/11 - Dom 27/11: 10 a.m. - 9 p.m.
(todas las horas son hora del este)

CONTÁCTENOS :info@jhheat.com

Hogar

Productos

whatsApp

contacto